Knowledge

Cleaning and maintenance of air purifiers

Cleaning and maintenance of air purifiers
In order to make the purifier work better, please perform the following maintenance in time when the cleaning indicator flashes to remind you to clean after a period of use.

Components Required for Cleaning Operations

1. Container: a container for cleaning the purification layer.

2. Special cleaning agent: Use a cleaning agent that does not corrode the ion box, internal aluminum electrodes, and resin.

3. Plastic gloves and protective sunglasses: Please wear gloves and protective glasses when cleaning to protect your hands and eyes.

cleaning method

1. When opening the back cover of the fuselage and pulling out the purification layer for cleaning, care should be taken to prevent deformation due to force. If the purification layer is not deformed, it is easy to cause failure.

2. Cleaning of the ion box: use a special cleaning agent, and control the spraying amount according to the turbidity of the ion box. Spray the aluminum sheet in the ion box evenly, and wait for about 10 minutes after spraying to let the cleaning agent dissolve the oil stains. Then rinse with water.

3. The stainless steel primary filter can be cleaned with a towel and water.

4. The formaldehyde filter and ozone filter are consumable materials, which cannot be cleaned due to long-term use and chemical synthesis.

post cleaning steps

1. The ion box should be dried naturally. Do not dry with towel fibers. Let dry for more than 12 hours in a well-ventilated place. Do not use hot air above 45 ℃, such as ovens, hair dryers, etc., otherwise it will cause deformation. An ion volume that is not completely dry can cause problems such as poor insulation.

2. After cleaning, check whether the ion box is normal and whether the electrode plate is deformed, bent and smooth. When electrodes are deformed or irregular, use flat-nose pliers to correct them.

3. After the cleaning is completed, turn on the power and the Changan cleaning button for more than 3 seconds to restore the reminder function, and then conduct a 3-minute test run.

You Might Also Like